I-Select TS100 / I-Select TW100 User Guide - Problem Solving
5 - 13
84F2
Server Management
Interface Failed
Contact your service representative to replace the system board.
84F3
Baseboard Management
Controller in Update Mode
Ask your service representative for maintenance.
84F4
Sensor Data Record
Empty
84FF
System Event Log Full
Clear the event log by using the BIOS SETUP utility. If the error is
not eliminated, contact your service representative to replace the
system board. The error message is displayed periodically if
ESMPRO is not installed. The event log must be cleared
periodically.
8500
Bad or missing memory in
Slot 3A
Check to see that the all DIMMs are firmly seated in the slot.
Contact your service representative to replace the memory or
system board.
8501
Bad or missing memory in
Slot2A
8502
Bad or missing memory in
Slot1A
8504
Bad or missing memory in
Slot 3B
8505
Bad or missing memory in
Slot 2B
8506
Bad or missing memory in
Slot 1B
8601
All memory marked as fail
Forcing minimum back
online
8306
OS Boot Watchdog Time
failure
Contact your service representative.
Table 5 - 2: POST Error Codes And Messages (Continued)
On-screen error message