Troubleshooting 10-17
Error Messages on Virtual LCD
NEC EXPRESSSCOPE Engine 2 (Remote Management Controller) on your server board allows
you to monitor the server status on the WEB browser-based screen of the client PC via network.
The virtual LCD (16 digits x 2 lines) in the "Host Information" area displays the POST codes and
status message.
When POST detects an error, the POST error code is displayed on the virtual LCD upon completion
of POST. See the table for POST error codes for details.
POWER ON
ATTENTION
Virtual LCD
Status indicators
Message send from BIOS
Message send from BMC
Example:
Messages displayed on upper line (BIOS message)
On-screen message
Description
Action
XX BIOS Rev XXXX
POST in progress.
XX: POST code, YYYY: BIOS version
Wait until POST completes.
Prepare To Boot
POST completes normally.
Mem Reconfigured
POST completes with memory degraded.
Contact your service
representative.
Mem Err Disable
A correctable memory error frequently
occurred.
CPU Reconfigured
POST completes with processor
degraded.
Memory C-Err XX
A correctable error frequently occurs in
DIMM #XX.
Memory U-Err XX
An uncorrectable error has occurred in
DIMM #XX.
PCI Bus SERR XX
A SERR has occurred in the PCI bus XX.
PCI Bus PERR XX
A PERR has occurred in the PCI bus XX.
Chipset Err XXXX
A chipset error occurred.
Summary of Contents for Express5800/iR120a-1E
Page 16: ...x This page is intentionally left blank ...
Page 34: ...1 18 Notes on Using Your Server This page is intentionally left blank ...
Page 158: ...5 30 Installing Windows Server 2008 4 Activate Windows The Windows activation is complete ...
Page 256: ...8 12 Installing and Using Utilities This page is intentionally left blank ...
Page 268: ...9 12 Maintenance This page is intentionally left blank ...
Page 372: ...C 2 IRQ This page is intentionally left blank ...
Page 374: ...D 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Page 378: ...E 4 Product Configuration Record Table This page is intentionally left blank ...