10-12 Troubleshooting
Messages displayed by RAID Controller during POST
On-screen message
Action
Memory/battery problems were detected.
The adapter has recovered, but cached data
was lost.
Press any key to continue, or 'C' to load the
configuration utility.
Contact your service representative.
Firmware version inconsistency was
detected.
The adapter has recovered, but cached data
was lost.
Press any key to continue, or 'C' to load the
configuration utility.
Contact your service representative.
Foreign configuration(s) found on adapter
Press any key to continue, or 'C' to load the
configuration utility.
Press
C
to run the utility to import or clear
configuration.
Previous configuration cleared or missing
Importing configuration created on
MM/DD hh:mm
Press any key to continue, or 'C' to load the
configuration utility.
Contact your service representative.
An enclosure was found that contains both
SAS and SATA drives, but this controller
does not allow mixed drive types in a single
enclosure. Please correct the problem then
restart your system.
Press any key to continue, or 'C' to load the
configuration utility.
RAID Controller may be faulty. Contact your service
representative to replace the RAID controller.
SAS drives were detected, but this controller
does not support SAS drives.
Please remove the SAS drives then restart
your system.
Press any key to continue, or 'C' to load the
configuration utility.
RAID Controller may be faulty. Contact your service
representative to replace the RAID controller.
SATA drives were detected, but this
controller does not support SATA drives.
Please remove the SATA drives then restart
your system.
Press any key to continue, or 'C' to load the
configuration utility.
RAID Controller may be faulty. Contact your service
representative to replace the RAID controller.
Invalid SAS topology detected. Please
check your cable configurations, repair the
problem, and restart your system.
Check if cable is connected properly. If the same
error persists, contact your service representative.
The battery hardware is missing or
malfunctioning, or the battery is unplugged.
If you continue to boot the system, the
battery-backed cache will not function.
Please contact technical support for
assistance.
Press 'D' to disable this warning (if your
controller does not have a battery).
<When battery is not used>
Press
D
to hide this message.
<When battery is used>
Check if battery is connected properly. If the same
error persists, contact your service representative.
Summary of Contents for Express5800/iR120a-1E
Page 16: ...x This page is intentionally left blank ...
Page 34: ...1 18 Notes on Using Your Server This page is intentionally left blank ...
Page 158: ...5 30 Installing Windows Server 2008 4 Activate Windows The Windows activation is complete ...
Page 256: ...8 12 Installing and Using Utilities This page is intentionally left blank ...
Page 268: ...9 12 Maintenance This page is intentionally left blank ...
Page 372: ...C 2 IRQ This page is intentionally left blank ...
Page 374: ...D 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Page 378: ...E 4 Product Configuration Record Table This page is intentionally left blank ...