Troubleshooting 10-9
Error
code
Error message
Recommended Action
02D1
System Memory exceeds the CPU's caching
limit.
02F4
EISA CMOS not writeable.
02F5
DMA Test Failed.
02F6
Software NMI Failed.
02F7
Fail-safe Timer NMI Failed.
Contact your service representative.
0611
IDE configuration changed
0612
IDE configuration error - device disabled
Check IDE configuration.
0613
Com A configuration changed
Check COM A configuration.
0614
Com A config. error - device disabled
0615
Com B configuration changed
Check COM B configuration.
0616
Com B config. error - device disabled
0B22
Processors are installed out of order.
Contact your service representative to
replace the CPU.
0B28
Unsupported CPU detected on CPU socket
1.
0B29
Unsupported CPU detected on CPU socket
2.
Make sure that the server supports the
CPU. If you are not sure, contact your
service representative to request the
maintenance.
0B42
Resource Conflict
Contact your service representative.
0B43
Warning: IRQ not configured
0B45
System configuration Data Write Error
0B60
CPU1_DIMM1 has been disabled
0B61
CPU1_DIMM2 has been disabled
0B62
CPU1_DIMM3 has been disabled
0B63
CPU1_DIMM4 has been disabled
0B66
CPU2_DIMM1 has been disabled
0B67
CPU2_DIMM2 has been disabled
0B68
CPU2_DIMM3 has been disabled
0B69
CPU2_DIMM4 has been disabled
0B6F
DIMM group with error is enabled.
0B70
The error occurred during temperature
sensor reading.
Contact your service representative.
0B71
System Temperature out of the range.
Contact your service representative to
replace the fan.
0B74
The error occurred during voltage sensor
reading.
Contact your service representative.
0B75
System voltage out of the range.
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check failed.
0B82
BMC Core Hardware failure.
0B83
BMC IBF or OBF check failed.
Turn off the power once and then on again
to start the server. If the error cannot be
corrected, contact your service
representative.
0B8A
BMC SEL area full.
Start the SETUP and select [Server] -
[Event Log configuration] - [Clear All Error
Logs] and press
Enter
to clear event logs.
Summary of Contents for Express5800/iR120a-1E
Page 16: ...x This page is intentionally left blank ...
Page 34: ...1 18 Notes on Using Your Server This page is intentionally left blank ...
Page 158: ...5 30 Installing Windows Server 2008 4 Activate Windows The Windows activation is complete ...
Page 256: ...8 12 Installing and Using Utilities This page is intentionally left blank ...
Page 268: ...9 12 Maintenance This page is intentionally left blank ...
Page 372: ...C 2 IRQ This page is intentionally left blank ...
Page 374: ...D 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Page 378: ...E 4 Product Configuration Record Table This page is intentionally left blank ...