49
NATIONAL
INSTRUMENTS
Table 4-4: J3 connector terminals and functions
Fig.4-4: J3 connector terminals and functions
4.3.2 J3 Connector Terminal and Function
Control and monitoring signals are isolated from the
power supply output.
Connector Technical Information
•
Connector type: IPL1-104-01-S-D-RA-K, SAMTEC
•
Receptacle type: IPD1-04-D-K, SAMTEC
•
Contact pins: CC79R-2024-01-L, SAMTEC
•
Hand tool: CAT-HT-179-2024-11, SAMTEC
•
Wire: AWG 20-24
Pin
Signal name
Function
Section
1
Programmed Signal 1
General Purpose Open collector Port 1
5.7.3
2
PS_OK
Output for indication of the power supply status. High level is OK.
5.7.4
3
Trigger Out
Trigger output, positive true, pulse width: Min. 10usec
8.5.2
4
ILC
Enable /Disable the power supply output by dry-contact (short/open). 5.7.2
5
Shut Off (SO)
Input for shut off control of the power supply output.
5.7.1
6
Programmed Signal 2
General Purpose Open collector Port 2
5.7.3
7
IFC_COM
Isolated interface, common.
8
Trigger In
CMOS level input for triggering power supply output. Positive edge,
pulse width: Min. 10usec.
8.5.1