WARNING:
Terminals 7, 9 and 12 of J1 are connected internally to the negative sense(-S) potential of the power
supply. Do not attempt to bias any of these terminals relative to the negative sense. Use the Isolated
Programming interface option to allow control from a programming source at a different potential
relative to the power supply negative.
CAUTION:
To prevent ground loops and to maintain the isolation of the power supply when programming from
J1, use an ungrounded programming source.
WARNING:
There is a potential shock hazard at the output when using a power supply with output greater
than 60VDC. Use wires with minimum insulation rating equivalent to the maximum output voltage
of the power supply.