2.3 RMX-4104 Series Specifications
RMX-4104
MODEL
N/A
20-40
36-24
60-14
100-8
1. Rated output voltage(*1)
V
20
36
60
100
2. Rated output
current (*2)(*21)
Vin ≥ 100Vac, Ta ≤ 50°C
A
40
24
14
8
85Vac ≤ Vin < 100Vac, Ta ≤ 40°C
A
40
24
14
8
85Vac ≤ Vin < 100Vac, 40°C < Ta ≤ 50°C
A
36
20
12.5
7.5
3. Rated output
power
Vin ≥ 100Vac, Ta ≤ 50°C
W
800
864
840
800
85Vac ≤ Vin < 100Vac, Ta ≤ 40°C
W
800
864
840
800
85Vac ≤ Vin < 100Vac, 40°C < Ta ≤ 50°C
W
720
720
750
750
CONSTANT VOLTAGE MODE
20-40
36-24
60-14
100-8
1. Max. Line regulation (*6)
---
0.01% of rated output 2mV
2. Max. Load regulation (*7)
---
0.01% of rated output 2mV
3. Ripple and noise (p-p, 20MHz) (*8)
mV
50
50
60
80
4. Ripple r.m.s. 5Hz~1MHz
mV
5
5
12
15
5. Temperature coefficient
PPM/°C
30PPM/°C from rated output voltage, following 30 minutes warm-up.
6. Temperature stability
---
0.05% of rated Vout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temp.
7. Warm-up drift
---
Less than 0.05% of rated output 2mV over 30 minutes following power on.
8. Remote sense compensation/wire
V
1
2
3
5
9. Up-prog. Response time, 0~Vomax.(*9)
mS
50
50
50
100
10. Down-prog. response time:
Full load (*9)
mS
25
25
25
80
Time delay (*17)
425
450
570
1370
No load (*10) (*15) (*17)
110
155
175
375
No load (*10) (*16) (*17)
470
470
500
1200
11. Transient response time
mS
Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated output current.
Output set-point: 10~100%, Local sense. Less than 1mS, for models up to and including 100V
12. Hold-up time (*18)
---
10mSec Typical. Rated output power.
CONSTANT CURRENT MODE
20-40
36-24
60-14
100-8
1. Max. Line regulation (*6)
---
0.01% of rated output 2mA
2. Max. Load regulation (*11)
---
0.01% of rated output 5mA
3. Load regulation thermal drift
---
For 10V: Less than 0.15% of rated output current over 30 minutes following load change.
For 20V ~ 100V: Less than 0.1% of rated output current over 30 minutes following load change.
4. Ripple r.m.s. 5Hz~1MHz
mA
100
31
28
12
5. Temperature coefficient
PPM/°C
100PPM/°C from rated output current, following 30 minutes warm-up.
6. Temperature stability
---
0.05% of rated Iout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
7. Warm-up drift
---
10V model: Less than +/-0.3%, 20V model: Less than +/-0.15%, 36V~100 models: Less than +/-0.1% of rated output current over
30 minutes following power on.
PROTECTIVE FUNCTIONS
20-40
36-24
60-14
100-8
1. Foldback protection
---
Output shut-down when power supply change mode from CV to CC or CC to CV. User presetable.
Reset by AC input recycle in autostart mode or by OUTPUT button or by rear panel ENABLE, or by communication port.
2. Over-voltage protection (OVP)
---
Inverter Shut down method. Reset by AC input recycle in autostart mode or by OUTPUT button or by rear panel ENABLE,
or by communication port.
3. Over - voltage trip point
V
1~24
2~40
5~66
5~110
4. Output under voltage limit (UVL)
---
Preset by front panel or communication port. Prevents from adjusting Vout below limit. Does not affect in analog programming.
5. Output under voltage protection (UVP)
---
Output shut-down when power supply output voltage goes below UVP programming. User presetable.
Reset by AC input recycle in autostart mode or by OUTPUT button or by rear panel ENABLE, or by communication port.
6. Over temperature protection
---
User Selectable. Latched or non latched