Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
Description
Parts of the object are, with respect to function, dependent on the currently selected mode.
OMS [3]
FR
EV
SO
EO
QS
OMS HALT
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
SO (Switched On)
Value = "1": Switches to the "Switched on" state
EV (Enable Voltage)
Value = "1": Switches to the "Enable voltage" state
QS (Quick Stop)
Value = "0": Switches to the "Quick stop" state
EO (Enable Operation)
Value = "1": Switches to the "Enable operation" state
OMS (Operation Mode Specific)
Meaning is dependent on the selected operating mode
FR (Fault Reset)
Resets an error (if possible)
HALT
Value = "1": Triggers a halt; valid in the following modes:
•
•
•
•
•
6041h Statusword
Function
This object returns information about the status of the CiA 402 Power State Machine.
Object description
Index
6041
h
Object name
Statusword
Object Code
VARIABLE
Data type
UNSIGNED16
Savable
no
Access
read only
PDO mapping
TX-PDO
Allowed values
Preset value
0000
h
Firmware version
FIR-v1426
Change history
Version: 1.0.1 / FIR-v1748
225