Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
Change history
Firmware version FIR-v1426: Subindex 01
h
: "Name" entry changed
from "Special Function Disable" to "Special Function Enable"
Firmware version FIR-v1512: The number of entries was changed
from 8 to 9.
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Preset value
08
h
Subindex
01
h
Name
Special Function Enable
Data type
UNSIGNED32
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
00000000
h
Subindex
02
h
Name
Function Inverted
Data type
UNSIGNED32
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
00000000
h
Subindex
03
h
Name
Force Enable
Data type
UNSIGNED32
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
00000000
h
Subindex
04
h
Name
Force Value
Data type
UNSIGNED32
Access
read / write
Version: 1.0.1 / FIR-v1748
198