14.
Never remove or tamper with the safety devices, guards or insulation fitted on the machine.
Every pressure vessel or auxiliary installed outside the machine to contain air above
atmospheric pressure must be protected by a pressure-relieving device or devices as required.
15.
Pipework or other parts with a temperature in excess of 80˚C (176˚F) and which may be
accidentally touched by personnel in normal operation must be guarded or insulated. Other
high-temperature pipework must be clearly marked.
16.
For water-cooled machines, the cooling water system installed outside the machine has to be
protected by a safety device with set pressure according to the maximum cooling water inlet
pressure.
17.
If the ground is not level or can be subject to variable inclination, consult the manufacturer.
Also consult following safety precautions: Safety precautions during operation and
Safety precautions during maintenance.
These precautions apply to machinery processing or consuming air or inert gas.
Processing of any other gas requires additional safety precautions typical to the
application which are not included herein.
Some precautions are general and cover several machine types and equipment;
hence some statements may not apply to your machine.
1.4
Safety precautions during operation
All responsibility for any damage or injury resulting from neglecting
these precautions, or non-observance of the normal caution and care
required for installation, operation, maintenance and repair, even if not
expressly stated, will be disclaimed by the manufacturer.
Precautions during operation
1.
Never touch any piping or components of the machine during operation.
2.
Use only the correct type and size of hose end fittings and connections. When blowing through
a hose or air line, ensure that the open end is held securely. A free end will whip and may
cause injury. Make sure that a hose is fully depressurized before disconnecting it.
3.
Persons switching on remotely controlled machines shall take adequate precautions to ensure
that there is no one checking or working on the machine. To this end, a suitable notice shall be
affixed to the remote start equipment.
4.
Never operate the machine when there is a possibility of taking in flammable or toxic fumes,
vapors or particles.
5.
Never operate the machine below or in excess of its limit ratings.
6.
Keep all bodywork doors shut during operation. The doors may be opened for short periods
only, e.g. to carry out routine checks. Wear ear protectors when opening a door.
7.
People staying in environments or rooms where the sound pressure level reaches or exceeds
90 dB(A) shall wear ear protectors.
8.
Periodically check that:
•
All guards are in place and securely fastened
•
All hoses and/or pipes inside the machine are in good condition, secure and not rubbing
•
There are no leaks
Instruction book
2987 2020 00
7
Summary of Contents for VDR 2600
Page 1: ...NANO Refrigerant dryers VDR 2600 VDR 3150 VDR 3700 VDR 4200 VDR 5050 Instruction book...
Page 2: ......
Page 28: ...Figure 17 Electrical diagram Instruction book 26 2987 2020 00...
Page 58: ...Dimension drawing of water cooled dryer imperial units Instruction book 56 2987 2020 00...
Page 59: ...Dimension drawing of air cooled dryer metric units Instruction book 2987 2020 00 57...
Page 62: ...Figure 22 Air cooled dryer Instruction book 60 2987 2020 00...
Page 94: ......