Dryer protection
The high-pressure shut-down switch (S1) stops the compressor motor when the pressure in the
refrigerant circuit reaches the upper set-point of the switch.
After tripping:
•
The switch must be reset manually by pressing its reset knob and by pressing reset key (//) on
the regulator (electronic regulator).
The compressor motor has a built-in thermic protection. If the thermic protection trips, the
compressor motor will be stopped. The compressor will restart when the motor windings have
cooled down, which may take up to 3 hours.
2.7
Connectivity and ICONS
General
The machine comes with a Touch controller which has an internal connectivity device. The Touch
controller allows read-out of a number of parameters of the machine on a user login-protected web
site called ICONS. The Touch controller has an integrated antenna.
Safety precautions
It is important to follow all regulations regarding the use of radio equipment, in particular regarding
the possibility of radio frequency (RF) interference. Please follow the safety advice given below
carefully.
•
Respect restrictions on the use of radio equipment in fuel depots, chemical plants or other
explosive environments.
•
Avoid operation close to inadequately protected personal medical devices such as hearing
aids and pacemakers. Consult the manufacturers of the medical device to determine if it is
adequately protected.
•
Avoid operation close to other electronic equipment which may also cause interference if the
equipment is inadequately protected. Observe any warning signs and manufacturer
recommendations.
•
Respect a distance from the human body of at least 20 cm (8 inch) during operation.
•
Do not operate the device in areas where cellular modems are not advised without proper
device certifications. These areas include environments where cellular radio can interfere,
such as explosive atmospheres, medical equipment, or any other equipment which may be
susceptible to any form of radio interference. The modem can transmit signals that could
interfere with this equipment.
ICONS
The machine is ICONS-ready.
ICONS is a web-based platform to monitor compressed air installations. It is available in 3 product
levels:
•
ICONS Service
ICONS Service rules out all uncertainties. Scheduling maintenance visits becomes as simple
and easy as it should be; the service log book is always just one click away and the online link
with the supplier allows to request and quickly receive quotes for spare parts or additional
services.
Instruction book
2987 2020 00
29
Summary of Contents for VDR 2600
Page 1: ...NANO Refrigerant dryers VDR 2600 VDR 3150 VDR 3700 VDR 4200 VDR 5050 Instruction book...
Page 2: ......
Page 28: ...Figure 17 Electrical diagram Instruction book 26 2987 2020 00...
Page 58: ...Dimension drawing of water cooled dryer imperial units Instruction book 56 2987 2020 00...
Page 59: ...Dimension drawing of air cooled dryer metric units Instruction book 2987 2020 00 57...
Page 62: ...Figure 22 Air cooled dryer Instruction book 60 2987 2020 00...
Page 94: ......
Page 95: ......