Rockhopper 38 – Maintenance Manual
208
AP-74038, Rev. 1.1, 25/01/05
9.3 ERRORS WHEN MESSAGE IS NOT DISPLAYED
9.3.1 Trouble with Initialization.
No
Message
Explanation
N°
Checkpoint
Action
1.1 • Is there a broken or shorted lead
in the switch cable assy (between
the switch and
power supply board)?
Use a tester to check for broken or
shorted leads.
→
Replace the switch cable
assy.
1.2 • Do the "Power supply voltage
check 100 V AC"
1.3 • Do the "Power supply voltage
check 5 V DC"
1.4 • Do the "Power supply voltage
check 24, 42 V DC"
1.5 • Check the panel cable
connectors on the panel board
and main board.
Are they inserted obliquely?
Are they securely locked?
Check Main board J110 (PANEL),
panel board J301 (MAIN)
→
Reconnect the
connectors.
1.6 • The panel cable may be faulty.
→
Replace it.
1.7 • Is there a fault in the panel board
assy liquid crystal display?
→
Replace the panel board
assy.
1 No
Power
Faulty LCD
(no display,
unstable
display)
1.8 • The main board assy may be
damaged.
→
Replace it.
Summary of Contents for Rockhopper 38
Page 1: ...Maintenance Manual MUTOH EUROPE N V AP 74038 Rev 1 1 25 01 2005 ...
Page 2: ...Rockhopper 38 Maintenance Manual 2 AP 74038 Rev 1 1 25 01 05 ...
Page 4: ...Rockhopper 38 Maintenance Manual 4 AP 74038 Rev 1 1 25 01 05 ...
Page 6: ...Rockhopper 38 Maintenance Manual 6 AP 74038 Rev 1 1 25 01 05 ...
Page 15: ...Rockhopper 38 Maintenance Manual 15 AP 74038 Rev 1 1 25 01 05 1 2 3 4 ...
Page 16: ...Rockhopper 38 Maintenance Manual 16 AP 74038 Rev 1 1 25 01 05 5 6 7 8 9 ...
Page 26: ...Rockhopper 38 Maintenance Manual 26 AP 74038 Rev 1 1 25 01 05 ...
Page 32: ...Rockhopper 38 Maintenance Manual 32 AP 74038 Rev 1 1 25 01 05 ...
Page 112: ...Rockhopper 38 Maintenance Manual 112 AP 74038 Rev 1 1 25 01 05 ...
Page 146: ...Rockhopper 38 Maintenance Manual 146 AP 74038 Rev 1 1 25 01 05 ...
Page 152: ...Rockhopper 38 Maintenance Manual 152 AP 74038 Rev 1 1 25 01 05 ...
Page 258: ...Rockhopper 38 Maintenance Manual 258 AP 74038 Rev 1 1 25 01 05 ...