Rockhopper 38 – Maintenance Manual
205
AP-74038, Rev. 1.1, 25/01/05
No
Message
Explanation
N°
Checkpoint
Action
1.1 • Use the self-
diagnostic
“Sensor/Origin” and
carry out the origin
sensor test.
1.2 • The origin sensor
assy connection J205
(H ORIGIN) on the
main board.
→
Reconnect
properly
1.3 • Check Y cable
connections. Are they
inserted obliquely?
Check. J111 (HEAD1)
on the main board and
J201 (MAIN1) on the
head board.
→
Insert them
properly.
→
Replace the Y
cable between J111
(HEAD1) on the main
board and J201
(MAIN1) on the head
board.
1.4 • The origin sensor
assy may be faulty.
→
Replace it
1.5 • The main board assy
may be damaged.
→
Replace it
1
E075 Error Sensor
Fault
This message indicates
that condition has
occurred in which the
origin cannot be
detected.
Caution :
Main board assy connector
J111 (HEAD1) and head
board assy connecter
J2021(MAIN1) should be
plugged in securely. The main
board may be damaged if
power is applied when they
are not properly connected.
Summary of Contents for Rockhopper 38
Page 1: ...Maintenance Manual MUTOH EUROPE N V AP 74038 Rev 1 1 25 01 2005 ...
Page 2: ...Rockhopper 38 Maintenance Manual 2 AP 74038 Rev 1 1 25 01 05 ...
Page 4: ...Rockhopper 38 Maintenance Manual 4 AP 74038 Rev 1 1 25 01 05 ...
Page 6: ...Rockhopper 38 Maintenance Manual 6 AP 74038 Rev 1 1 25 01 05 ...
Page 15: ...Rockhopper 38 Maintenance Manual 15 AP 74038 Rev 1 1 25 01 05 1 2 3 4 ...
Page 16: ...Rockhopper 38 Maintenance Manual 16 AP 74038 Rev 1 1 25 01 05 5 6 7 8 9 ...
Page 26: ...Rockhopper 38 Maintenance Manual 26 AP 74038 Rev 1 1 25 01 05 ...
Page 32: ...Rockhopper 38 Maintenance Manual 32 AP 74038 Rev 1 1 25 01 05 ...
Page 112: ...Rockhopper 38 Maintenance Manual 112 AP 74038 Rev 1 1 25 01 05 ...
Page 146: ...Rockhopper 38 Maintenance Manual 146 AP 74038 Rev 1 1 25 01 05 ...
Page 152: ...Rockhopper 38 Maintenance Manual 152 AP 74038 Rev 1 1 25 01 05 ...
Page 258: ...Rockhopper 38 Maintenance Manual 258 AP 74038 Rev 1 1 25 01 05 ...