The quantity of
seed or fertiliser
is lower than
indicated by the
calibration test.
1. The bottom
ap position is
incorrect
1. Adjust the position of the bottom ap in accordance
with section 6.5.8. ADJUSTING THE BOTTOM FLAP
POSITION or section 6.5.11. ADJUSTING THE BOTTOM
FLAP POSITION IN THE FEEDER UNITS OF THE SMALL
2. The
calibration test
table is
indicative
2. Check the feeding quantity by means of the
calibration test in accordance with section 6.7.
3. The seed or
fertiliser
bridging has
occurred in the
hopper.
4. The feeder
roller is
obstructed.
4. Clean the feeder roller in accordance with
section 7.3.5. CLEANING THE FEEDER UNITS or
section 7.3.6. CLEANING THE SMALL SEED HOPPER
5. The wheel
drive operation
is compromised
5. Check the operation of the wheel drive in
accordance with section 7.1.6. CHECKING THE
TIGHTNESS OF THE WHEEL DRIVE CHAIN and
section 7.1.7. INSPECTING THE WHEEL DRIVE
The machine
cannot be lifted
1. The lift inhibit
function is
enabled
1. Disable the lift inhibit function in accordance with
section 4.2. RDS G-WIZARD
2. Machine
lifting circuit
ball valve is
closed
2. Open the machine lifting circuit ball valve in the
hydraulic hose
3. The quick
coupling is open
3. Check the connection of the quick coupler
The machine
cannot be
lowered
1. Machine
lifting circuit
ball valve is
closed
1. Open the machine lifting circuit ball valve in the
hydraulic hose
2. The quick
coupling is open
2. Check the connection of the quick coupler
3. The stoppers
are in place in
the lifting
cylinder
3. Remove the stoppers from the lifting cylinder
Hopper alarm
does not
function
1. The alarm has
been disabled
1. Enable the alarm from the settings in accordance
with section 4.2. RDS G-WIZARD
Operation and maintenance
manual
1.00
Cerex 300
154 (156)
Summary of Contents for Cerex 300 SeedPilot
Page 159: ...Hydraulic schematic Appen dix 2 Cerex 300 1 Appendix 2 Hydraulic schematic...
Page 160: ...Hydraulic schematic Appen dix 2 Cerex 300 2...
Page 161: ...Electrical Diagram Annex 3 Cerex 300 1 Annex 3 Electrical Diagram...
Page 162: ...Electrical Diagram Annex 3 Cerex 300 2...