![multicomp pro MP720021 Manual Download Page 93](http://html1.mh-extra.com/html/multicomp-pro/mp720021/mp720021_manual_1854297093.webp)
User Manual
88
Figure 4-25
Mean:
The arithmetic mean over the entire waveform.
PK-PK:
Peak-to-Peak Voltage.
RMS:
The true Root Mean Square voltage over the entire waveform.
Max:
The maximum amplitude. The most positive peak voltage measured over the
entire waveform.
Min:
The minimum amplitude. The most negative peak voltage measured over the
entire waveform.
Vtop:
Voltage of the waveform's flat top, useful for square/pulse waveforms.
Vbase:
Voltage of the waveform's flat base, useful for square/pulse waveforms.
Vamp:
Voltage between Vtop and Vbase of a waveform.
OverShoot:
Defined as (Vmax-Vtop)/Vamp, useful for square and pulse
waveforms.
PreShoot:
Defined as (Vmin-Vbase)/Vamp, useful for square and pulse
waveforms.
Cycle RMS:
The true Root Mean Square voltage over the first entire period of the
waveform.
Cursor RMS:
The true Root Mean Square voltage over the range of two cursors.
The automatic measurement of time parameters
The oscilloscopes provide time parameters auto-measurements include Period,
Frequency, Rise Time, Fall Time, +D width, -D width, +Duty, -Duty, Delay
A→B , Delay A→B , Screen Duty , Phase
A→B , and Phase
A→B .
Summary of Contents for MP720021
Page 1: ...i Digital Storage Oscilloscope 100MHz Model MP720025...
Page 5: ...v Appendix B General Care and Cleaning 147 Appendix C Battery Using Guide 148...
Page 27: ...User Manual 22 Control the vertical cursor line Switch to select the lines...
Page 36: ...User Manual 31 Figure 4 1 Hamming window Figure 4 2 Rectangle window...
Page 37: ...User Manual 32 Figure 4 3 Blackman window Figure 4 4 Hanning window...
Page 38: ...User Manual 33 Figure 4 5 Kaiser window Figure 4 6 Bartlett window...