REG REGISTER TITLE FEATURE DESCRIPTIONS W/ CONTROL NUMBERS
YOUR SETTING
REG
OPERATING 0
-
"PASSlVE OFF"
- No
power is supplied to equipment regardless of ring
# .
01
MODES
1 - "PASSlVE ON"
-
Power is supplied to
equipment regardless of # of rings
*
2 -"POWER ON CALL"
-
Power supplied when inbound call rings are
detected. Power turned off at the end of a call (within 2 minutes).
3 - "REBOOT"
-
When ring # is detected, power is stopped tor 15 seconds.
4 - "TOGGLE" - Power is switched (on or off) with each subsequent call.
REG
RINGS TO
2 - "2 OR LESS RINGS"
- When two or less rings are detected The Power
02 AUTOMATIC Stone will perform operating modes 2 thru 4.3 rlngs or more
OPERATION
-
will not react.
*
3 - "3 OR MORE RINGS"
-
When 3 or more rings are detected, The Power
Stone will perform operating modes 2 thru 4.2 or less rings
- will not react.
REG DISTINCTiVE
*
1 - Single Ring Cadence Sensitive to only a single ring cadence
03 RING
2 - Double Ring Cadence Sensitive to ‘double ring’ transmitted by phone Co.
CADENCE 3 -Triple Ring Cadence Sensitive to "triple ring’ transmitted by phone Co.
SENSITIVITY
REG
AUDIO/ANSWER
0
- AUDIO/ANSWER 15 Rlngs- Tha Power Stone answers at 15 rings and
04
NO. OF RINGS
transmits power status tones (same as Reg. 07).
FEATURE
Will hold the line for 10 sec.
1 -
AUDIO/ANSWER 3 Rings- The Power Stone answers at three rings and
transmits power status tones (same as Reg. 07).
Will hold the line for 10 sec.
REG
0 - ‘Normal Operation" The Power Stone will operate in the programmed
05 BUTTON
operating mode when the proper # of rings are detected.
OVERRIDE 1 - ‘Dverride’- Operating modes are overridden and power is supplied to
equipment constantly regardless of Register 2 setting.
REG
*
OO - No Security Access Code- To enter manual control, all you dial is ##88
06
SECURITY
_ _ ?
-
To add 2 characters to the end of the securfty access code strfng.
FEATURE
REG
POWER STATUS
0 -Audible 2 low Beeps tells you no power is supplied to your equipment.
07 (REA0 ONLY - NON 1 - Audible 1 Bip tells you power is supplied to your equipment,
PRDGAMMABLE
REG POWER FAILURE 0 - Audible 2 low Beeps tells you there has been no power failure since
08 STATUS the last reading of this register.
(READ ONLY - NON 1 -Audible 1 Bip tells you there has been a power failure since the
PROGAMMABLE last reading of the register.
*
DENOTES
FACTORY PRESETS
Programming Commands
“##88”-
The factory preset code for access to Manual Operating Mode and programming.
Command “60”
-
Set registers 01, 02,03, 04,05, and 06 to factory presets.
Command “80”
-
Save current contents of registers to memory and exit manual control.
Command “90”
-
Exit manual control without saving changes to register. All registers will be restored
with the values last saved in memory.
NOTE: Registers 07 and 08 are nonprogrammable and when accessed will audibly “read-out” status of
power and immediate history of power failure at the site. Register 05, “Override always reverts to the
preset when a power outage occurs.