Alarm messages
52
V3.20151130_rev.2
30283620-02-EN
Alarm text
Possible cause
Remedial measure
range exceeded.
or lower than the set speed.
metering roll.
Metering shaft is stationary. The revolution sensor on the metering shaft does
not register any movement of the metering shaft.
Stop immediately!
Remediate the cause.
Fan is rotating too slowly.
The current fan speed is lower than the value for
the "Min. Rotational Speed" parameter.
Increase the fan speed or change the "Min.
Rotational Speed" parameter for the fan.
Fan is rotating too fast.
The current fan speed is higher than the value of
the "Max. Rotational Speed" parameter.
Decrease the fan speed or change the "Max.
Rotational Speed" parameter for the fan.
Pressure is too high.
The pressure of a linear sensor exceeds the
value for the "Maximum Value" parameter.
Reduce the pressure or change the "Maximum
Value" parameter.
Pressure is too low.
The pressure of a linear sensor is below the value
for the "Minimum Value" parameter.
Increase the pressure or change the "Minimum
Value" parameter.
Hopper is low.
There is not enough seed or fertilizer in the
hopper.
Fill the hopper.
Hopper is empty.
There is no more seed or fertilizer in the hopper. Fill the hopper.
Error in blockage system.
An error has occurred in the blockage system.
Check the blockage system.
Seed flow detected.
Seed flow has occurred in a tramline.
Check the tramline control.
No seed flow detected.
The blockage system has not detected any seed
flow.
Check the blockage system.
Input is too high.
The entered value is too high.
Enter a lower value.
Input is too low.
The entered value is too low.
Enter a higher value.
Charger fault.
There is a malfunction in the alternator of the
charger.
Check the alternator of the charger.
The metering was stopped
because the working
position was not reached.
Raise the implement.
The implement is not in working position.
Raise the implement.
Error with the initialisation of
the Control Layer
configuration.
There was an error in the Control Layer
configuration.
Check the configuration.
Right half width is not
activated.
The right half width is shut off.
Activate the right half width.
Right half width is not shut
off.
The right section is activated.
Shut off the right half width.