Mounting and installation
Installing the sensors on the implement
4
30283620-02-EN
V3.20151130_rev.2
17
Schematic overview
Min. 25 mm
Attachment angle
Distance 15-25mm
Sensor (red cap)
South pole of the magnet (red side)
Magnet (nonmagnetic attachment, e.g. V2A,
copper, brass)
Connector pin assignment
3-pin AMP connector
Pin
Cable colour
Designation
1
white
0VE
2
brown
3
green
Signal
Spare part number
Item number
Designation
30303615
Reed contact sensor with AMP plug
Installing the speed sensor
Radar sensors are suitable as speed sensors.
Consult the operating instructions for the radar sensor to find out how it has to be installed.
4.2.4