8
Configuring the on-board integrated display/controller for work
Selecting and configuring the speed source
40
V3.20151130_rev.2
30283620-02-EN
Configuring the on-board integrated display/controller for work
Selecting and configuring the speed source
You must enter the source from which the on-board integrated display/controller obtains the current
speed. The configuration procedure can differ depending on the speed source.
Possible speed sources
Source
To configure the speed source
Impulse-transmitting speed
sensor mounted on the
implement
Calibrating the speed sensor using the 100m method [
Simulated speed
Entering the simulated speed [
Calibrating the speed sensor with the 100m method
When calibrating the speed sensor with the 100m method, you determine the number of pulses
received by the speed sensor in a distance of 100m. When you know the amount of impulses, the job
computer can calculate the current speed.
After the first calibration, you can enter the number of impulses manually as a value for the
"
Calibration factor
" parameter.
1.
Drive the implement onto the field.
2.
Mark the tire position on the ground. For example with a stone.
3.
Measure a straight route of 100 m and mark the end.
4.
On the work screen, press:
>
> (
)
⇨
"
Settings / Speed
" screen appears.
5.
In the "
Speed source
" parameter, select the "
Implement
" value
6.
- Call up the
"Calibration"
screen.
⇨
"
Calibration
" screen appears.
7.
- Start the calibration.
8.
Travel the marked route.
⇨
During travel, the counted impulses are displayed in the "
No. of impulses
" field.
9.
- Press when you have reached the end.
⇨
The calibration is terminated.
8
8.1
8.1.1
Procedure