633 – SD P-Ambient Air (HDT2800)
ZKP-Number: 1.0700.087
Moisture sensor signal error (TRICAN HDT2800)
Yellow alarm - warning
Cause
Corrective action
Moisture sensor (TRICAN
HDT2800) defective.
1. Check sensor and wiring, replace as necessary (→ Page 181).
2. Contact Service.
634 – SD T0-Ambient Air (HDT2800)
ZKP-Number: 1.0700.089
Moisture sensor signal error (TRICAN HDT2800)
Yellow alarm - warning
Cause
Corrective action
Moisture sensor (TRICAN
HDT2800) defective.
1. Check sensor and wiring, replace as necessary (→ Page 181).
2. Contact Service.
635 – SD Air Humidity (HDT2800)
ZKP-Number: 1.0700.091
Moisture sensor signal error (TRICAN HDT2800)
Yellow alarm - warning
Cause
Corrective action
Moisture sensor (TRICAN
HDT2800) defective.
1. Check sensor and wiring, replace as necessary (→ Page 181).
2. Contact Service.
636 – SD Level Lube Oil J1939
ZKP-Number: 1.0700.105
Oil level sensor J1939 signal error
Yellow alarm - warning
Cause
Corrective action
Oil level sensor J1939 faulty.
1. Check sensor and wiring, replace as necessary (→ Page 181).
2. Contact Service.
637 – SD T-Lube Oil, Oil Pan J1939
ZKP-Number: 1.0700.107
Oil temperature sensor J1939 signal error
Yellow alarm - warning
Cause
Corrective action
Oil temperature sensor J1939
defective.
1. Check sensor and wiring, replace as necessary (→ Page 181)
2. Contact Service.
100 | Troubleshooting | MS150096/01E 2012-08
TIM-ID: 0000029153 - 006