612 – AL Wiring Pressure Regulating Valve 1
ZKP-Number: 1.1301.903
Wiring faulty, pressure regulating valve 1
Yellow alarm - warning
Cause
Corrective action
Cable break or short circuit on
PWM channel, pressure
regulating valve 1.
1. Check wiring (→ Page 181).
2. Contact Service.
613 – AL Wiring Pressure Regulating Valve 2
ZKP-Number: 1.1302.903
Wiring faulty, pressure regulating valve 2
Yellow alarm - warning
Cause
Corrective action
Cable break or short circuit on
PWM channel, pressure
regulating valve 2.
1. Check wiring (→ Page 181).
2. Contact Service.
614 – AL L1 P-Fuel Add. Filter Diff.
ZKP-Number: 2.0119.001
Fuel prefilter differential pressure too high
Yellow alarm - warning
Cause
Corrective action
Fuel prefilter not operating
correctly.
1. Replace fuel prefilter.
2. Contact Service.
615 – AL EIL Protection
ZKP-Number: 2.0610.951
Alarm for Protection module
Red alarm – warning
Cause
Corrective action
Incorrect or manipulated EIL.
1. Replace EIL.
2. Contact Service.
616 – AL EIL Fault
ZKP-Number: 1.0610.952
ECU cannot detect EIL
Yellow alarm - warning
Cause
Corrective action
Incorrect or manipulated EIL.
1. Replace EIL.
2. Contact Service.
MS150096/01E 2012-08 | Troubleshooting | 97