599 – AL L2 PRV Faulty
ZKP-Number: 1.1302.901
Red alarm breather valve, second rail.
Cause
Corrective action
HP fuel block jamming or HP fuel
control block wiring faulty.
1. Check wiring and HP fuel control block (→ Page 181).
2. Contact Service.
600 – SD T-Exhaust A+B
ZKP-Number: 1.8004.646
Exhaust temperature sensor signal error, A- and B-side
Yellow alarm - warning
Cause
Corrective action
Exhaust temperature sensor on
A- and B-side faulty.
Short circuit or wire break.
1. Check sensor and wiring, replace as necessary (→ Page 181).
2. Contact Service.
601 – SD ETC1+ETC2
ZKP-Number: 1.3011.227
ETC speed sensor 1 and 2 signal error
Yellow alarm - warning
Cause
Corrective action
ETC speed sensors 1 and 2
faulty.
Short circuit or wire break.
1. Check sensor and wiring, replace as necessary (→ Page 181).
2. Contact Service.
602 – AL CAN Engine Start Lock
ZKP-Number: 2.1090.930
Start interlock signal from plant pending.
Yellow alarm - warning
Cause
Corrective action
Start interlock initiated by plant.
u
The alarm is reset by canceling the engine start command or the
CAN request.
606 – AL Double Nodes Lost CAN 1+2
ZKP-Number: 2.0500.691
ECU does not detect monitored CAN bus device.
Red alarm - forced idle
Cause
Corrective action
A node has failed on both CANs.
Short circuit or wire break.
1. Check wiring and power supply of plant (→ Page 181).
2. Acknowledge alarm.
3. Restart engine (→ Page 35).
4. Contact Service.