410 – LO U-PDU
ZKP-Number: 2.0141.921
Injector voltage too low (limit value 1)
Yellow alarm - warning
Cause
Corrective action
Cable damage or faulty power
supply.
1. Check wiring (→ Page 181).
2. Check power supply.
3. Contact Service.
411 – LOLO U-PDU
ZKP-Number: 2.0141.922
Injector voltage too low (limit value 2)
Red alarm - engine shutdown
Cause
Corrective action
Cable damage or faulty power
supply.
1. Check wiring (→ Page 181).
2. Check power supply.
3. Acknowledge alarm.
4. Contact Service.
412 – HI U-PDU
ZKP-Number: 2.0141.931
Injector voltage too high (limit value 1).
Yellow alarm - warning
Cause
Corrective action
Cable damage or faulty power
supply.
1. Check wiring (→ Page 181).
2. Check power supply.
3. Contact Service.
413 – HIHI U-PDU
ZKP-Number: 2.0141.932
Injector voltage too high (limit value 2)
Red alarm - engine shutdown
Cause
Corrective action
Cable damage or faulty power
supply.
1. Check wiring (→ Page 181).
2. Check power supply.
3. Acknowledge alarm.
4. Contact Service.
82 | Troubleshooting | MS150096/01E 2012-08
TIM-ID: 0000029153 - 006