466 – SD T-AUX 2
ZKP-Number: 1.8004.586
Signal fault, temperature Aux 2
Yellow alarm - warning
Cause
Corrective action
Analog input for Aux 2
temperature faulty.
Short circuit or wire break.
1. Check temperature sensor and wiring, replace as necessary
(→ Page 181).
2. Contact Service.
468 – SD T-AUX 1
ZKP-Number: 1.8004.579
Signal fault, temperature Aux 1
Yellow alarm - warning
Cause
Corrective action
Analog input for Aux 2
temperature faulty.
1.
2.
470 – SD T-ECU
ZKP-Number: 1.8004.587
Engine governor, temperature, signal error
Yellow alarm - warning
Cause
Corrective action
Temperature sensor for engine
governor faulty.
Short circuit or wire break.
1. Check sensor and wiring, replace as necessary (→ Page 181).
2. Engine restart (→ Page 35).
3. Contact Service.
471 – SD Suction Restrictor
ZKP-Number: 1.8004.592
Signal error suction restrictor
Yellow alarm - warning
Cause
Corrective action
Actuation of suction restrictor
faulty.
Short circuit or wire break.
1. Check sensor and wiring, replace as necessary (→ Page 181).
2. Contact Service.
86 | Troubleshooting | MS150096/01E 2012-08
TIM-ID: 0000029153 - 006