Raw water circuit (open circuit)
Number of cylinders
12
Raw water pump: Inlet pressure, min.
L bar
-0.4
Raw water pump: Inlet pressure, max.
L bar
+0.5
Pressure loss in off-engine raw water system, max.
L bar
0.7
Lube oil system
Number of cylinders
12
Lube oil operating temperature before engine, from
R °C
82
Lube-oil operating temperature before engine, to
R °C
90
Lube oil operating pressure before engine, from
R bar
7.5
Lube oil operating pressure before engine, to
R bar
8.5
Lube oil operating pressure (low idle) (meas. point: before engine)
R bar
3
Fuel system
Number of cylinders
12
Fuel pressure at engine inlet connection, min. (when engine is starting)
L bar
-0.3
Fuel pressure at engine inlet connection, min. (when engine is running)
L bar
-0.3
Fuel pressure at engine inlet connection, max. (when engine is starting)
L bar
+0.25
Fuel supply flow, max.
A Liters/min
5.5
General operating data
Number of cylinders
12
Firing speed, from
R rpm
100
Firing speed, to
R rpm
120
Starter (electric)
Number of cylinders
12
Starter rated voltage (standard design)
R V=
24
Inclinations - standard oil system (reference: waterline)
Number of cylinders
12
Longitudinal inclination, continuous max. driving end down (Option: max.
operating inclinations)
L Degrees
(°)
15
Longitudinal inclination, temporary max. driving end down (Option: max. op‐
erating inclinations)
L Degrees
(°)
22.5
Longitudinal inclination, continuous max. driving end up (Option: max. oper‐
ating inclinations)
L Degrees
(°)
0
Longitudinal inclination, temporary max., driving end up (Option: max. oper‐
ating inclinations)
L Degrees
(°)
10
Transverse inclination, continuous max. (Option: max. operating inclina‐
tions)
L Degrees
(°)
22.5
Transverse inclination, temporary max. (Option: max. operating inclinations) L Degrees
(°)
32.5
M015700/06E 2012-06 | Technical Data | 31
TIM-ID: 0000003008 - 003