RAW WATER CIRCUIT (open circuit)
Number of cylinders
16
Raw water pump: inlet pressure, min.
L bar
-0.4
Raw water pump: inlet pressure, max.
L bar
+0.5
Pressure loss in the off-engine raw water system, max.
L bar
0.7
LUBE OIL SYSTEM
Number of cylinders
16
Lube oil operating temperature before engine, from
R °C
78
Lube oil operating temperature before engine, to
R °C
86
Lube oil operating pressure before engine, from
R bar
6.5
Lube oil operating pressure before engine, to
R bar
7.5
Lube oil operating pressure (low idle) (meas. point: before engine)
R bar
2.5
FUEL SYSTEM
Number of cylinders
16
Fuel pressure at engine supply connection, min. (when engine is starting)
L bar
-0.3
Fuel pressure at engine supply connection, min. (when engine is running)
L bar
-0.3
Fuel pressure at engine supply connection, max. (when engine is starting)
L bar
+0.25
Fuel supply flow, max.
R liter/min
7.3
GENERAL OPERATING DATA
Number of cylinders
16
Firing speed, from
R rpm
100
Firing speed, to
R rpm
120
STARTING (electric)
Number of cylinders
16
Starter, rated voltage (standard design)
R V=
24
INCLINATIONS, STANDARD OIL SYSTEM (reference: waterline)
Number of cylinders
16
Longitudinal inclination, continuous max., driving end down (Option: max.
operating inclinations)
L degree
15
Longitudinal inclination, temporary max., driving end down (Option: max.
operating inclinations)
L degree
22.5
Longitudinal inclination, continuous max., driving end up (Option: max. op‐
erating inclinations)
L degree
0
Longitudinal inclination, temporary max., driving end up (Option: max. oper‐
ating inclinations)
L degree
10
Transverse inclination, continuous max. (Option: max. operating inclina‐
tions)
L degree
22.5
Transverse inclination, temporary max. (Option: max. operating inclinations) L degree
32.5
34 | Technical Data | M015700/06E 2012-06
TIM-ID: 0000003101 - 001