10V2000
Position
Cylinder
1
2
3
4
5
6
7
8
9
Firing TDC in cylinder A1
Bank A
E A
- -
- -
- A
E -
Bank B
E -
- -
- A
E A E -
Overlap TDC in cylinder A1
Bank A
- -
E A E A
E -
- A
Bank B
- A
E A E -
- -
- A
“E” = inlet valve clearance adjustment permitted, “A” = exhaust valve clearance adjustment permitted
12V2000
Position
Cylinder
1
2
3
4
5
6
7
8
9
Firing TDC in cylinder A1
Bank A
E A
E -
- A
E -
- A - -
Bank B
E -
- -
- A
E -
E
A
- A
Overlap TDC in cylinder A1
Bank A
- -
- A
E -
- A
E - E A
Bank B
- A
E A E -
- A
- - E -
“E” = inlet valve clearance adjustment permitted, “A” = exhaust valve clearance adjustment permitted
16V2000
Position
Cylinder
1
2
3
4
5
6
7
8
9
Firing TDC in cylinder A1
Bank A
E A - A - A
E - - A E - - - - -
Bank B
E -
- A - -
E - E
A
E - E
A
- A
Overlap TDC in cylinder A1
Bank A
- -
E - E -
- A E - - A E
A
E A
Bank B
- A
E - E A
- A - - - A - - E -
“E” = inlet valve clearance adjustment permitted, “A” = exhaust valve clearance adjustment permitted
18V2000
Position
Cylinder
1
2
3
4
5
6
7
8
9
Firing TDC in cylinder A1
Bank A
E A E -
- A
E - - A - - - A - -
- -
Bank B
- A
- A - -
E A - - E
A
E - E A
E -
Overlap TDC in cylinder A1
Bank A
- -
- A E -
- A E - E A E - E A
E A
Bank B
E -
E - E A
- -
E
A
- - - A - -
- A
“E” = inlet valve clearance adjustment permitted, “A” = exhaust valve clearance adjustment permitted
4.
Use feeler gauge to determine the distance between valve bridge and rocker arm.
5.
If the deviation from the reference value exceeds 0.1 mm, adjust valve clearance.
74 | Task Description | M015700/06E 2012-06
TIM-ID: 0000004363 - 003