7.2 Fuel System
7.2.1 Fuel system – Venting
Preconditions
☑
Engine is stopped and starting disabled.
☑
Engine cooled down to ambient temperature.
Special tools, Material, Spare parts
Designation / Use
Part No.
Qty.
Torque wrench, 4–20 Nm
F30044239
1
Ratchet adapter
F30027340
1
WARNING
Fuels are combustible.
Risk of fire and explosion!
• Avoid open flames, electrical sparks and ignition sources.
• Do not smoke.
Venting fuel prefilter
1.
Unlock fuel priming pump, screw out han-
dle (1).
Note:
Catch emerging fuel with a suitable cloth.
2.
Loosen threaded vent plug (2) and screw
out by approx. 3 to 4 turns.
3.
Operate the pump with the handle (1) until
bubble-free fuel emerges from the vent
plug (2).
4.
Close threaded vent plug (2) and tighten by
hand.
Note:
Catch emerging fuel with a suitable cloth.
5.
Loosen threaded vent plugs (3) and screw
out by approx. 3 to 4 turns.
6.
Operate the pump with the handle (1) until
bubble-free fuel emerges from the vent
plug (2).
7.
Close threaded vent plug (2) and tighten by
hand.
MS15033/02E 2015-02
| Task Description | 87
TIM-ID: 0000028012 - 004