10 – SS T-Coolant Intercooler (Limit 2)
ZKP-Number: 2.0124.932
Yellow alarm; power limitation < 20%;
Cause
Corrective action
Coolant temperature in
intercooler too high.
1. Reduce power.
2. Check engine lines for leaks. Check coolant cooler for leaks,
contamination and operation.
3. Contact Service.
15 – LO P-Lube Oil
ZKP-Number: 2.0100.921
Yellow alarm; warning
Cause
Corrective action
Lube oil pressure too low.
u
Check oil level, top up as necessary (→ Page 97).
16 – SS P-Lube Oil (Limit 2)
ZKP-Number: 2.0100.922
Red alarm; engine stop
Cause
Corrective action
Lube oil pressure too low.
1. Check oil level, top up as necessary (→ Page 97).
2. Acknowledge alarm.
3. Restart engine (→ Page 29).
4. Request towing locomotive if required.
19 – HI T-Exhaust A
ZKP-Number: 2.0126.931
Yellow alarm; warning
Cause
Corrective action
Exhaust gas temperature (A-
side) too high.
1. Reduce power.
2. Check air filter.
3. Request towing locomotive if required.
20 – SS T-Exhaust A
ZKP-Number: 2.0126.932
Red alarm; power reduction ≥ 20%
Cause
Corrective action
Exhaust gas temperature (A-
side) too high.
1. Reduce power.
2. Check air filter.
3. Request towing locomotive if required.
MS15033/02E 2015-02
| Troubleshooting | 41
TIM-ID: 0000047144 - 003