354 – AL Open Load Cylinder B4
ZKP-Number: 1.8004.553
Yellow alarm; warning
Cause
Corrective action
Open circuit in cylinder injector
wiring. Result: Misfiring.
u
Check solenoid valve.
355 – AL Open Load Cylinder B5
ZKP-Number: 1.8004.554
Yellow alarm; warning
Cause
Corrective action
Open circuit in cylinder injector
wiring. Result: Misfiring.
u
Check solenoid valve.
356 – AL Open Load Cylinder B6
ZKP-Number: 1.8004.555
Yellow alarm; warning
Cause
Corrective action
Open circuit in cylinder injector
wiring. Result: Misfiring.
u
Check solenoid valve.
361 – AL Power Stage Low (Internal Electronic Failure)
ZKP-Number: 1.8004.496
Red alarm; engine stop
Cause
Corrective action
Internal electronic fault,
electronics possibly faulty.
1. Observe any other messages.
2. Check solenoid valve wiring (→ Page 119).
3. Acknowledge alarm.
4. Restart engine (→ Page 29).
5. Request towing locomotive if required.
362 – AL Power Stage High (Internal Electronic Failure)
ZKP-Number: 1.8004.497
Red alarm; engine stop
Cause
Corrective action
Internal electronic fault,
electronics possibly faulty.
1. Observe any other messages.
2. Check solenoid valve wiring (→ Page 119).
3. Acknowledge alarm.
4. Restart engine (→ Page 29).
5. Request towing locomotive if required.
60 | Troubleshooting | MS15033/02E 2015-02
TIM-ID: 0000047144 - 003