188 – AL CAN2 Bus Off
ZKP-Number: 2.0500.688
Yellow alarm; warning
Cause
Corrective action
CAN controller 2 is in "Bus-Off"
status. Automatic changeover to
CAN 1; short circuit; massive
interference or baud rate
incompatibility.
1. Check CAN bus for short circuit, rectify short circuit as
necessary.
2. Check shielding, improve shielding as necessary.
189 – AL CAN2 Error Passive
ZKP-Number: 2.0500.689
Yellow alarm; warning
Cause
Corrective action
CAN controller 2 has signaled a
warning.
1. Check CAN bus for short circuit, rectify short circuit as
necessary.
2. Check shielding, improve shielding as necessary.
201 – SD T-Coolant
ZKP-Number: 1.8004.570
Yellow alarm; power limitation < 20%;
Cause
Corrective action
Coolant temperature sensor
faulty; short circuit or wire
break.
u
Check sensors B6.1, B6.3, and cabling , replace if necessary
(→ Page 119).
203 – SD T-Charge Air
ZKP-Number: 1.8004.571
Yellow alarm; power limitation < 20%;
Cause
Corrective action
Charge-air temperature sensor
faulty; short circuit or wire
break.
u
Check sensors B9.1, B9.2, B9.3, and cabling , replace if
necessary (→ Page 119).
204 – SD Level Lube Oil
ZKP-Number: 1.8004.602
Optional yellow alarm; warning
Cause
Corrective action
Lube oil level sensor faulty;
short circuit or wire break.
u
Check sensor B93 and wiring, replace as necessary
(→ Page 119).