596 – AL Develop PR Set
ZKP-Number: 1.8004.645
Yellow alarm; warning
Cause
Corrective action
Standard production data record
available. The data record stored
is for testing.
u
Contact Service.
598 – AL L1 UDV Defekt Rail 2
ZKP-Number: 1.1302.900
Yellow alarm; warning
Cause
Corrective action
Pressure relief valve of second
rail faulty.
u
Check pressure relief valve, replace as necessary.
599 – AL L2 UDV Defekt Rail 2
ZKP-Number: 1.1302.901
No alarm, fault is entered
Cause
Corrective action
Pressure relief valve of second
rail faulty.
u
Check pressure relief valve, replace as necessary.
600 – SD T-Exhaust A+B
ZKP-Number: 1.8004.646
Red alarm; power reduction ≥ 20%
Cause
Corrective action
Exhaust temperature sensor on
A and B sides defective; short
circuit or wire break.
u
Check sensors B4.21, B4.22, and cabling , replace if necessary.
602 – AL CAN Engine Start Lock
ZKP-Number: 2.1090.930
Yellow alarm; warning
Cause
Corrective action
Start interlock initiated by plant.
1. Check plant configuration.
2. Restart engine (→ Page 29).
3. Request towing locomotive if required.
70 | Troubleshooting | MS15033/02E 2015-02
TIM-ID: 0000047144 - 003