334 – AL Wiring Cylinder B4
ZKP-Number: 1.8004.533
Yellow alarm; warning
Cause
Corrective action
Short circuit in cylinder injector
wiring. Result: Misfiring.
u
Check solenoid valve.
335 – AL Wiring Cylinder B5
ZKP-Number: 1.8004.534
Yellow alarm; warning
Cause
Corrective action
Short circuit in cylinder injector
wiring. Result: Misfiring.
u
Check solenoid valve.
336 – AL Wiring Cylinder B6
ZKP-Number: 1.8004.535
Yellow alarm; warning
Cause
Corrective action
Short circuit in cylinder injector
wiring. Result: Misfiring.
u
Check solenoid valve.
341 – AL Open Load Cylinder A1
ZKP-Number: 1.8004.540
Yellow alarm; warning
Cause
Corrective action
Open circuit in cylinder injector
wiring. Result: Misfiring.
u
Check solenoid valve.
342 – AL Open Load Cylinder A2
ZKP-Number: 1.8004.541
Yellow alarm; warning
Cause
Corrective action
Open circuit in cylinder injector
wiring. Result: Misfiring.
u
Check solenoid valve.
343 – AL Open Load Cylinder A3
ZKP-Number: 1.8004.542
Yellow alarm; warning
Cause
Corrective action
Open circuit in cylinder injector
wiring. Result: Misfiring.
u
Check solenoid valve.
58 | Troubleshooting | MS15033/02E 2015-02
TIM-ID: 0000047144 - 003