232 – SD Charger 1 Speed
ZKP-Number: 1.3011.128
Yellow alarm; warning
Cause
Corrective action
Speed sensor of primary
turbocharger faulty; short circuit
or wire break.
u
Check sensor B44.1 and wiring, replace as necessary
(→ Page 119).
233 – SD Charger 2 Speed
ZKP-Number: 1.3011.129
Yellow alarm; warning
Cause
Corrective action
Speed sensor of primary
turbocharger faulty; short circuit
or wire break.
u
Check sensor B44.2 and wiring, replace as necessary
(→ Page 119).
239 – SD P-Diff Fuel
ZKP-Number: 1.8004.598
Yellow alarm; warning
Cause
Corrective action
Pressure sensors for differential
fuel pressure faulty; short circuit
or wire break.
Fault only occurs in connection.
u
Check sensors B34.1, B34.2, and cabling , replace if necessary
(→ Page 119).
240 – SD P-Fuel
ZKP-Number: 1.8004.565
Yellow alarm; warning
Cause
Corrective action
Fuel pressure sensor after fuel
main filter defective; short
circuit or wire break.
u
Check sensors B34.1, B34.2, and cabling , replace if necessary
(→ Page 119).
245 – SD ECU Power Supply Voltage
ZKP-Number: 2.8006.589
Yellow alarm; warning
Cause
Corrective action
Internal engine governor fault;
electronics faulty.
u
Replace engine governor.
MS15033/02E 2015-02
| Troubleshooting | 55
TIM-ID: 0000047144 - 003