LambdaDriver 400 & 800
ML46430, Rev. 07
October 2004
TM-SFP Transponders:
1. Jumper JP7 is set in the RED position, as shown in
2. Two mutually redundant transponders operating with the same channel (wavelength) and
connected with a Y-cable must be placed in two adjacent slots, so that the odd-number
slot has the smaller number. Valid slot pairs are: 1,2 and 3,4 and 5,6 and 7,8 and 9,10.
TM2-SFP Transponders:
1. Jumper JP2 is set in the TRANS-RED position, as shown in
(
As noted there, Transponders 1 and 2 of the TM2-SFP transponder module will operate
in mutual redundancy mode.)
TM-DXFP Transponders:
1. DIP switch SW1 toggle 1 is set in the RED position, as shown in
2. Two mutually redundant transponders operating with the same channel (wavelength) and
connected with a Y-cable must be placed in two adjacent slots, so that the odd-number
slot has the smaller number. Valid slot pairs are: 1,2 and 3,4 and 5,6 and 7,8 and 9,10.
199