![MRV Communications LambdaDriver 400 User Manual Download Page 162](http://html1.mh-extra.com/html/mrv-communications/lambdadriver-400/lambdadriver-400_user-manual_1846064162.webp)
LambdaDriver 400 & 800
ML46430, Rev. 07
October 2004
Notes
Counter 1 shows the number of frames received from the remote port by the local
port.
Counter 2 shows the number of error bits in the frames received from the remote
port by the local port.
Command
Description Clear module counters.
Syntax
clear-trans-counters opt.[arg #0] opt.[arg #1]
opt.[arg #0] = <slot>-<slot>-<slot>
and/or
<slot>..<slot>
i.e., individual slot numbers separated by
hyphens, or range of slot numbers.
opt.[arg #1] = <port>-<port>-<port>
and/or
<port>..<port>
i.e., individual port numbers separated by
hyphens, or range
(
1..2
) of port numbers.
opt.[arg #0] = all
opt.[arg #1] = all
Example
SYS_console>clear-trans-counters 8 1
Clear Port 1 Counters at slot 8
Notes
–
clear-trans-counters
Default
Command
get-oa-parameters
Description Show optical amplifier parameters.
Syntax
get-oa-parameters [arg #0]
[arg #0] = <slot>-<slot>-<slot>
and/or
<slot>..<slot>
i.e., individual slot numbers separated by
hyphens, or range of slot numbers.
Default
–
Example
SYS_console>get-oa-parameters 5
Optical Amplifier Parameters
*****************************
Module Configuration and Type Module Version, S/N
----------------------------- -------------------
Module Temperature
Pump-2 Max Drive Current : 266.0(mA) Pump-1 Power : 0.00(mW)
Rated Gain : 15.00(dB)
Configuration : Dual Pump Hardware Version : 2.0
Module Type : Amplet Software Version : 2.2
Serial Number : 33 3
------------------
Temperature : 30.7 (C)
Pump Current and P/S Voltage Optical Power
---------------------------- -------------
Pump-1 Drive Current : 1.5(mA) Input Power : -34.86(dBm)
Pump-1 Max Drive Current : 236.0(mA) Output Power : -13.00(dBm)
Pump-2 Drive Current : 0.0(mA) Module Gain : 21.86(dB)
Pump-2 Power : 0.00(mW)
Power Supply Voltage : 3.44(V) Maximum Power : 18.00(dBm)
162