LambdaDriver 400 & 800
ML46430, Rev. 07
October 2004
or
−
200 to 240 Vac, 0.4 A, 50 Hz – for other countries
DC: -48 to -60 Vdc
DC rated equipment must be installed under the following conditions:
1. The DC supply source to which the LDX00 is to be connected must be isolated from
the alternating current source and reliably connected to earth or to a DC (SELV)
source.
2. The LDX00 must be installed only in restricted access areas (Dedicated Equipment
Rooms, Equipment Closets, or the like) in accordance with Articles 110-16, 110-17,
and 110-18 of the National Electrical Code, ANSI/NFPA 70.
3. Input wiring to a terminal block must be routed and secured in such a manner that it
is protected from damage and stress. Do not route wiring past sharp edges or moving
parts.
4. A readily accessible disconnect device, with a 3 mm minimum contact gap shall be
incorporated in the fixed wiring.
5. A listed circuit breaker suitable for protection of the branch circuit wiring and rated 48
Vdc minimum must be provided.
Note
It is recommended to connect the LDx00 through a UPS to ensure
continued operation even when the line (mains) power gets cut off.
Grounding
Reliable earthing of the LDX00 must be maintained. Particular attention should be paid to supply
connections when connecting to power strips, rather than to direct connections to the branch
circuit.
Networking
Multiplexing
Singlemode 9/125
µ
m fiberoptic cables for interconnecting the LDx00s. The length of cabling
supported depends on the power budget and cable attenuation. The power budget is given in.
The cable attenuation is specified by the cable manufacturer. The required type of cable
connector depends on the connector of the module to which the cable is to be connected. The
module connectors are specified in Appendix J.
Management
Out
band Management using Serial/RS-232 Connection
•
Craft terminal (asynchronous ASCII terminal, e.g.,
VT100
terminal),
or
Craft terminal emulator (e.g., PC with asynchronous ASCII terminal emulation software
application such as
Microsoft Windows’ HyperTerminal
).
•
OS (e.g.,
Microsoft Windows 95/98/2000/NT/XP
).
•
Null-modem (straight, uncrossed) serial RS-232 cable with DB-9 9-pin
female
connector
not
longer than 15 m (50 ft).
In
band Management using TELNET or SNMP Connection
•
TELNET station (e.g., PC with TELNET application)
or
SNMP NMS
•
OS (e.g.,
Microsoft Windows 95/98/2000/NT/XP
)
102