LambdaDriver 400 & 800
ML46430, Rev. 07
October 2004
Table 18: Front Panel LEDs
Module
LED
Status
Significance
ON-Green
Power distribution OK.
Power
Supply
PWR
OFF
Power distribution faulty.
ON-Green
Reception at access port OK.
ACCESS RX
OFF
Reception at access port faulty.
ON-Green
Reception at WDM port OK.
WDM RX
OFF
Reception at WDM port faulty.
ON-Red
WDM Transmission laser faulty.
LASER OFF
OFF
WDM Transmission laser OK.
ON-Red
Module too hot.
Transponder
TMP ALRM
OFF
Module temperature OK.
ON-Green
Power to module OK.
PWR
OFF
Power to module faulty.
ON-Green
SNMP data flowing.
MGT
OFF
No SNMP data flowing.
ON-Green
Ethernet data flowing.
ACT (Eth)
OFF
No Ethernet data flowing.
ON-Green
Ethernet link OK.
LINK (Eth)
OFF
Ethernet link faulty.
ON-Green
OSC data flowing.
OSC ACT
OFF
No OSC data flowing.
ON-Green
OSC link OK.
Management
OSC LINK
OFF
OSC link faulty.
ON-Green
Primary link selected.
1+1
Redundancy
P-SEL
OFF
Primary link deselected.
ON-Green
Secondary link selected.
S-SEL
OFF
Secondary link deselected.
ON-Green
Primary link receive port OK.
P-RX
OFF
Primary link receive port faulty.
ON-Green
Secondary link receive port OK.
S-RX
OFF
Secondary link receive port faulty.
ON-Green
Port (1, 2, 3, or 4) link to network
OK
.
ESCON
Multiplexer
L (1, 2, 3, or 4)
OFF
Port (1, 2, 3, or 4) link to network
faulty
.
ON-Green
Reception at port (1, 2, 3, or 4)
synchronized.
A (1, 2, 3, or 4)
OFF
Reception at port (1, 2, 3, or 4)
not
synchronized.
L
ON-Green
Multiplex port link to network
OK
.
OFF
Multiplex port link to network
faulty
.
29
When S-SEL LED is OFF, P-SEL LED should be ON, and vice versa.
137