LambdaDriver 400 & 800
ML46430, Rev. 07
October 2004
Local
Mux or OADM to
Remote
Mux or
OADM
(between two LDx00s)
100 km (62.1 mi)
Cable Type:
Singlemode 9/125
µ
m
Cable Connectors:
MiniSC (MU)
ACCESS TX
Port (Access Transmit Port)
Purpose:
Connection to access equipment
receive port
Cable
Fiber
Length (max):
XFP-10GD-LR 10
km
XFP-10GD-SR 2
km
Cable Type:
Singlemode 9/125
µ
m
Cable Connectors:
Per the SFP (usually LC)
ACCESS RX
Port (Access Receive Port)
Purpose:
Connection to access equipment
transmit port
Cable
Fiber
Length (max):
XFP-10GD-LR 10
km
XFP-10GD-SR 2
km
Cable Type:
Singlemode 9/125
µ
m
Cable Connectors:
Per the SFP (usually LC)
APD Overload for Transponder-to-Mux/Demux
module connection (Max)
- 2 dBm
LEDs
LASER OFF (ALS/APR):
WDM transmission laser status
TMP ALRM:
Temperature status
WDM RX:
WDM port reception status
ACC RX:
Access port reception status
Mounting Handle/ejector/extractor
Posidrive screws (two)
Physical Dimensions (W x H x D):
26.93 mm (1.06 in) x
130.7 mm (5.145 in) x
227.5 mm (8.956 in)
Weight (max):
0.55 kg (1.21 lb)
Appendix K lists some of the available SFPs.