SAFETY INFORMATION: Always read before proceeding.

WARNING

This manual contains both information and warnings that are necessary for
the safe operation and maintenance of the clampmeter. It is recommended
that you read the instructions carefully and ensure that the contents are fully
understood. Failure to understand and to comply with the warnings and
instructions can result in serious injury, damage or even death.

In order to avoid the danger of electrical shock, it is important that proper
safety measures are taken when working with voltages exceeding 30V AC
rms, 42V AC peak or 60V DC.

The clampmeter must only be used under the conditions and for the 
purposes for which it has been constructed. Particular attention should be
paid to these warnings, the precautions, the technical specifications and
the use of the CM56 in dry surroundings.

Always inspect your clampmeter, test leads and accessories for any sign of 
damage before use. If any abnormal conditions exist (e.g: broken test
leads, cracked case, display not reading, etc.), do not attempt to use it. Do
not expose it to direct sunlight, excessive temperature or moisture.

Keep this manual for future reference. Updated instructions and 
product information are available at: www.martindale-electric.co.uk

SYMBOLS:

Equipment complies with relevant EU Directives

AC (Alternating Current)

Ground

Direct Current

Equipment protected by Double Insulation (Class II)

Caution - refer to accompanying documents

Caution - risk of electric shock

End of life disposal of this equipment should 
be in accordance with relevant EU Directives

CONTENTS

1

Introduction

2

1.1

Description

2

1.2

Unpacking & Inspection

4

1.3

Replacing the Battery

4

2

Safety Information

5

3

Operation

6

3.1

Voltage Measurement

6

3.2

Current Measurement

6

3.3

Resistance Measurement

8

3.4

Continuity Testing

8

3.5

Diode Testing

9

3.6

Frequency Measurements

9

4

Maintenance

10

4.1

Cleaning

10

4.2

Repair & Service

10

4.3

Storage Conditions

10

5

Warranty

10

Technical Specifications

1

WARNING

READ "SAFETY INFORMATION" BEFORE USING THE METER

1

2

3

4

5

6

9

8

10

7

2

1. INTRODUCTION

This manual contains information and warnings which must be followed to ensure
safe operation of the clampmeter.

This clampmeter is a handheld 3200-count instrument that is designed for use in
the laboratory, field servicing and any circumstance where high current 
measurement is required. The clampmeter incorporates a finger guard which
ensures the safety of the user whilst operating the instrument, a rugged case that
is shock resistant and fire retardant and electronic overload protection for all
functions and ranges. In addition, a protective carrying case is included for
protection of the meter whilst not in use.

1.1 Description

Summary of Contents for CM56

Page 1: ...ilable at www martindale electric co uk SYMBOLS Equipment complies with relevant EU Directives AC Alternating Current Ground Direct Current Equipment protected by Double Insulation Class II Caution refer to accompanying documents Caution risk of electric shock End of life disposal of this equipment should be in accordance with relevant EU Directives CONTENTS 1 Introduction 2 1 1 Description 2 1 2 ...

Page 2: ...The instrument complies with class II overvoltage CAT III 1000V of the IEC1010 1 EN61010 1 UL3111 1 and CAN CSA C22 2 1010 1 92 standards pollution degree 2 in accordance with IEC 664 indoor use If the equipment is used in a manner not specified the protection provided by the equipment may be impaired This product complies with the requirements of the following European Community Directives 89 336...

Page 3: ...nals of the clampmeter 8 WARNING Attempting resistance or continuity measurements on live circuits can cause electrical shock damage to the instrument and damage to the equipment under test Resistance measurements must be made on de energised DEAD circuits only for maximum personal safety The electronic overload protection installed in this instrument will reduce the possibility of damage to the i...

Page 4: ...d 1 0 rdg 3d 1 0 rdg 3d 1 0 rdg 3d 1 5 rdg 3d 2 5 rdg 5d 0 7mA 0 13mA 13μA 1 3μA 0 13μA 0 13μA Range Resolution Accuracy Test Current Open Circuit Volts 3 2V 1mV 10 rdg 2d 0 6mA 3 0VDC typical Test Current Resoiution Range Resolution Accuracy Input Impedance 320mV 3 2V 32V 320V 1000V 100μV 1mV 10mV 100mV 1V 0 5 rdg 1d 0 5 rdg 1d 0 5 rdg 1d 0 5 rdg 1d 0 5 rdg 1d 1000MΩ 11MΩ 10MΩ 10MΩ 10MΩ AC Volts ...