4-10
Setup and Operation
Key Field
Description
G
5
Configures operating parameters for optional
PORT
5. Configure the data and baud
options as described for
PORT
2, if present. Select async or sync (internal clock,
external clock, or slv on rx clock). The INTFC menu displays UNEQPD if the
communications board is not present and configured. Refer to the
operate.txt
file
in Appendix C, “Initialization Information.”
H
6 MOD
Displays the INTFC 6 menu. Refer to Setting up
PORT
6 (the RF modulator) for
instructions on setting up the modulator port.
I
7 GEN
Displays the INTFC 7 menu that shows the MPEG message generator port, for
example, GEN_PORT 03 EA-PID 1503H.
INTFC 1 Menu
⎯
Viewing
PORT
1 (RS-232 Console Port) Settings
To view the RS-232 console port setting, select
1
CONSOLE
and then press
ENT
. The menu
displays asynchronous communications at 9600 baud.
INTFC 2 Menu
⎯
Setting Up
PORT
2 (RS-530/RS-232)
To configure operating parameters for
PORT 2
:
1
Select
2 530/232
and then press
ENT
to display the RS-232 menu.
2
Select the
data rate field
, press or to select the
data rate
(300, 600, 1200, 2400, 4800,
9600, 19.2K), and then press
ENT
.
INTFC 3 Menu
⎯
Setting Up
PORT
3 (Ethernet)
To configure operating parameters for
PORT
3
:
1
Select
3 ENET
and then press
ENT
to display the
fields for the MAC address, TTL settings,
IGMP settings, and a menu selection for the assigned multicast MAC receive address.
Figure 4-5 illustrates the INTFC 3-ENET menu:
Figure 4-5
INTFC 3 ENET menu
A
B
C
E
D
F
OM 1000 Installation and Operation Manual