4-12
Setup and Operation
3
If you select SYNC, press or to select
INTERNAL CLK
,
EXTERNAL CLK
,
SLV,
or
RX CLK
. The INTFC menu displays UNEQPD if the communications board is not present
and configured.
4
Select
DATA RATE
, press or to select the
rate
, and then press
ENT
. Refer to the data
(bit) rate table in Appendix A, “Specifications” for valid values.
INTFC 6 Menu
⎯
Setting Up
PORT
6 (RF Modulator)
To set up the RF modulator, you must:
Enable the modulator output mode
Set the output frequency
Set the output signal level
Figure 4-7 illustrates the process that you must follow to set up the modulator port. Default
settings are shown in bold:
Figure 4-7
Setting up the RF modulator
INTFC
menu
Modulator
selection
6 MOD
RF
modulator
setup menu
Port
selection
Modulator
mode
71.00
•
•
•
•
•
•
129.00
75.25
Output signal
level
1
•
•
•
•
•
•
40
35
Back to
INTFC menu
UP
OM 1000 Installation and Operation Manual