Initialization
Information
C-11
8 0 0 0 1 9600 0 0 0 0 0 0 0
#Group
3
3 0 0 0 0 0 0 0 0 0 0 0 0
- - -
a b c
where: (use with Group 3 (ethernet) ONLY!)
-----------------------
a = multicast rcv MAC upper byte (in decimal)
b = multicast rcv MAC middle byte (in decimal)
c = multicast rcv MAC lower byte (in decimal)
example: 256 24064 543 (=01:00:5E:00:02:1F)
--- ----- --- ----- ----- -----
a b c (= a b c )
If an optional RS-530 or RS-232 module is installed, the
following configuration changes must be made before the module(s)
become available on the front panel menu. Use the following
entry in the PhysicalTable section in place of either the
Group 4 (port 4) or Group 5 (port 5) entry, depending on which
slot the module is installed in. This tells the software the
module is installed and setup for 9600 bps async. The module
can then be configured as needed from the front panel.
Under "PhysicalTable", "Group 4" or "Group 5":
De
Entry (no module installed
fault
):
1 0 0 0 0 0 0 0 0 0 0 0 0
For
232
cards:
RS-
6 0 0 0 1 9600 0 0 0 0 0 0 0
For
530
cards:
RS-
7 0 0 0 1 9600 0 0 0 0 0 0 0
OM
SN
OM-1000 logical port assigments and there associated service
1000.
M
name must be specified in this file. This is not used within
the OM-1000 itself, but is passed along intact to the ACC-4000D
upon registration. See file header for format. Service names
must be recognizable by the ACC-4000D.
OM
SV
Network services and their ethernet port and protocol are
1000.
C
listed here. The OM-1000 uses this file to select the control
device port and protocol (usually 5167/tcp). See the file
header
for
format.
OM 1000 Installation and Operation Manual