OPERATING INSTRUCTIONS
M68HC11EVB/D
4-45
45
4.8.5
IBM-PC (with PROCOMM) to EVB
To perform the IBM-PC to EVB downloading procedure with PROCOMM, perform/observe the
following:
1. Invoke the PROCOMM.EXE program.
2. Setup PROCOMM to match EVB baud rate and protocol (type (Alt)S, then the
number 2) as follows:
9600 baud, no parity, 8-bits, 1-stop bit, full duplex
3. Setup ASCII transfer parameters (type (Alt)S, then the number 6) as follows:
Echo Local - Yes
Expand Blank Lines - Yes
Pace Character - 0
Character pacing - 25 (1/1000 second)
Line Pacing - 10
CR Translation - None
LF Translation - None
Save above settings to disk for future use.
4. Apply power to EVB.
5. Press IBM-PC keyboard carriage return <CR> key to display applicable EVB monitor
prompt.
6. Enter EVB monitor download command as:
>LOAD T
(Press RETURN after entering LOAD T.)
7. Instruct PROCOMM to send the S-record file by pressing the Pg Up key on the PC,
then follow PROCOMM instructions on the display screen to select the S-record file.
Motorola S-record file is now transferred to the EVB.
Upon completion of the S-record transfer, the following message is displayed:
done
>