GTR 8000 Base Radio
2
If the base radio and receivers are powered up, ensure that each device is switched to service mode or powered
down, as follows:
If you choose to turn off the power, set the rocker switch on the front of the associated power supply to
the Off (0) position and skip this step.
a. Connect to the base radio's transceiver module Ethernet service port using Configuration/Service Software
(CSS). See
4.4.4 Connecting Through an Ethernet Port Link, page 4-11
.
b. Using CSS, select
File → Read Configuration From Device
from the menu.
c. Select
Service → Test and Measurement Screen
from the menu.
d. Click
Change to Service Mode
.
e. Disconnect the Ethernet cable from the base radio's transceiver module Ethernet service port.
f. Repeat for each device in the configuration.
3
Remove the fan module to gain access to the Transceiver Option Card (TOC) on the transceiver module. See
9.3 Replacing the Fan Assembly, page 9-10
for details.
4
Connect cables to each device according to its relevant wiring diagram.
For a T2-2R Receiver Mute configuration,
See
Figure A-1 T2-2R Receiver Mute Option Kit
for details.
For a T3-3R Receiver Mute configuration,
See
Figure A-2 T3-3R Receiver Mute Option Kit
for details.
For a T4-4R Receiver Mute configuration,
See
Figure A-5 T4-4R Receiver Mute Option Kit
for details.
For a Tn-nR Receiver Mute configuration,
See
Figure A-6 Tn-nR Receiver Mute Option Kit
for details.
See
Figure A-3 T4-4R Receiver Mute Configuration
for an example of how to route cables.
5
Replace the fan modules for the base radio and receivers. See
9.3 Replacing the Fan Assembly, page 9-10
If you chose to turn off the power, set the rocker switch on the front of the associated power supply
to the On (1) position.
6
If the base radio and receivers are in service mode, switch each device to normal mode, as follows:
a. Connect to the base radio's transceiver module Ethernet service port using Configuration/Service Software
(CSS). See
4.4.4 Connecting Through an Ethernet Port Link, page 4-11
.
b. Select
File → Read Configuration From Device
from the menu.
c. Select
Service → Test and Measurement Screen
from the menu.
d. Click
Change to Normal Mode
.
e. Disconnect the Ethernet cable from the base radio's transceiver module Ethernet service port.
A-12
6871022P86-A - November 2012
Summary of Contents for GTR 8000
Page 2: ......
Page 4: ......
Page 6: ......
Page 14: ......
Page 18: ......
Page 22: ......
Page 26: ......
Page 60: ......
Page 177: ...5 8 1 3 VHF Tuning Procedure Figure 5 1 Preselector Tuning VHF 6871022P86 A November 2012 5 7 ...
Page 181: ...5 8 2 3 UHF Tuning Procedure Figure 5 2 Preselect Tuning UHF 6871022P86 A November 2012 5 11 ...
Page 230: ......
Page 234: ......
Page 244: ......
Page 286: ......
Page 300: ......
Page 338: ......