9.5 Replacing a Power Supply Fan
9.5 Replacing a Power Supply Fan
The power supply fan is a field replaceable unit (FRU).
Replacing the power supply fan requires that the entire power supply module be removed. The power
supply output is directly mapped to a PA/transceiver combination. Removal of a power supply will result
in a loss of the associated transmit channel until the replacement power supply is inserted and turned ON.
It is recommended that you disable the channel before replacing the module, so that the system does not
attribute the loss of channel to a failure. You can disable a channel using both the Unified Event Manager
or the Configuration/Service Software (CSS).
The Power Supply module contains dangerous voltages which can cause electrical shock to people or
damage to equipment.
Figure 9-5
Power Supply Fan
6871022P86-A - November 2012