5.11.3 Measuring HPD BR Tx Power, Frequency Accuracy and Tx EVM
5.11.3 Measuring HPD BR Tx Power, Frequency Accuracy
and Tx EVM
Procedure Steps
1
Perform the service monitor setup steps in
5.11.1 Setting Up the HPD Service Monitor for Testing the Base
.
2
Configure the service monitor T/R port to receive transmissions from the base radio, as follows:
• Click the
T/R
soft key under
RF In
on the right side of the screen.
3
Maximize the RF Control Settings window, by clicking the upper left corner of the window.
Figure 5-25
HPD Service Monitor - RF Control Settings Window (Aeroflex 3900 Series Service
Monitor)
6871022P86-A - November 2012
5-49