- 39 -
3.0 PROGRAMMING
3.0 PROGRAMMING
AND
AND
OPERATING
OPERATING
YOUR
YOUR
ROVI-MPS SYSTEM
ROVI-MPS SYSTEM
The Rovi-MPS system uses a programmable Tipsy Angle Sensor and feedback actuator motors to set all
the required safety limits and lockouts for the wheelchair. This includes programmed settings for the
Home position, the Maximum Tilt (or Tilt/Recline) Limit, the Drive Lockout Limit and the Reduced Drive
Speed Limit. Refer to
Section 4.3.4 Tipsy Angle Sensor
for more detailed information on the recommended
safety limit settings.
When operating your Rovi-MPS system thru an 8-way switch, the LED indicator lights on the switch
control box provide a visible indicator to notify if/when the wheelchair has reached the established safety
limits for
Reduced Drive Speed
(
RDS
) and/or
Drive Lockout
(
DLO
):
3.5.7 THRU SWITCH SAFETY INDICATORS
(for
REDUCED DRIVE SPEED
&
DRIVE LOCKOUT
:
REDUCED DRIVE SPEED (RDS)
:
The RDS Limit places the wheelchair into a reduced drive speed
(prior to DLO) when the seating system is tilted and/or reclined beyond
a preset angle, or raised beyond the ‘home” position for the Elevate/
Stand functions. When the Rovi-MPS system is in reduced drive
speed, the LED indicator lights are “
Flashing RED
“.
I.
S
WITCH
I
NDICATORS FOR
RDS
AND
DLO
8-WAY SWITCH CONTROL
DRIVE LOCKOUT
(
DLO
):
The DLO Limit prevents the wheelchair from driving when the seating
system is tilted and/or reclined beyond a preset (safe) operating angle.
When the Rovi-MPS system is in drive lockout, the LED indicator lights
are “
Solid RED
”.
LED indicator lights
*NOTE:
In order to return the wheelchair to normal drive speed, the affected power positioning function
must be returned to its established ‘Home’ position. (When the Rovi-MPS System is in the ‘Home’
position, the LED indicator lights remain
GREEN
).