© MOBATIME
29 / 84
800847.08
6.5.6
Time-keeping
Path: 2 Configuration
2 Time handling
2 Time adjustment setting
1. Adjust mode:
0=time is slowly adjusted (accord. to "Max. catch-up speed")
1=time is set immediately
2. Maximum catch up speed in ns/s (0-
10'000’000).
3. Quartz type:
Standard=0 (0-255)
4. Synch. only offset: 0=off
100-5000ms=Limits as from which time is no longer accepted
Alarm “Syn only diff too great“
For a description of time-keeping see Chapter
DTS 4128.timeserver Moser-Baer AG
====================================
TIME ADJUSTMENT CONFIGURATION
1 Adjustmode (0=follow, 1=set) 0
2 Max. catch up speed 100000ns/s
3 Time core type (0-255, default 0) 0
4 Synch. only offset 0ms
98 Return and save
99 Return and discard changes
Enter desired menu number>