Important:
Redundant Multicast time server:
If in the same network two NTP server should send NTP with same
Multicast IP address (redundancy), then the first time server has to be
configured with a small
pollinterval
(e.g. 2
sec.) and second time
server with a large pollinterval (min. 100 x larger, e.g. 9
512 seconds).
As long as the first time server is sending NTP Multicast packets, the
packets from second time server are ignored. This configuration is
needed, to reach a defined situation for the end devices (the DTS with the
more frequently NTP send rate gets higher priority for time reception).
Time zone table for the NTP slave clock line:
Path: 2 Configuration
1 Line
2 NTP slave clocks / time zone server
8 Configure time zone
table8
Display of all time zone entries (15) of time zone servers for NTP slave clock lines.
Choose a zone number to change selected zone.
Time zone selection (see chapter 6.5.21 Time zone selection).
The page can be exited with 99. Changes are first stored or reset on the overlying menu
page.
6.5.4
Time administration
Under time administration, settings can be undertaken for the following functions:
Time source configuration
see chapter 6.5.5
Time-keeping configuration
see chapter 6.5.6
Redundant Operation
see chapter 6.5.7
NTP Server
see chapter 6.5.8
For setting the time manually / Leap second
see chapter 6.5.9
DTS 4128.timeserver Moser-Baer AG
====================================
TIME ZONE - TABLE
Zone01: 2 [+1] Brussel Zone02: 2 [+1] Brussel
Zone03: 0 [0] UTC Zone04: 19 [+9] Tokyo
Zone05: 3 [+1] Athens Zone06: 8 [+3] Kuwait
Zone07: -1 Unknown season Zone08: -1 Unknown season
Zone09: -1 Unknown season Zone10: -1 Unknown season
Zone11: -1 Unknown season Zone12: -1 Unknown season
Zone13: -1 Unknown season Zone14: -1 Unknown season
Zone15: -1 Unknown season
Enter requested entry
Press enter for next part, 99 to leave>